material mounds are generally stiffer than dredged sediments, they are usually
still categorized as soft soils within the geotechnical community. Therefore, it is
prudent to test the foundation soils in the fixed ring device, although the standard
loading sequence may be used.
A representative sample of the fine-grained (minus No. 40 sieve) portion of
sediments to be dredged should be used for the standard oedometer test. Since
sediments have typically been remolded during the dredging process and any
internal structure existing in situ in the channel has been destroyed, a remolded
sample can be used for this test. The samples of foundation soils for consolida-
tion testing, however, should be undisturbed.
When soft disturbed sediment samples are used, they are often spooned into
the consolidation device. In this case, the dredged material must be placed
carefully into the consolidometer to prevent inclusion of air bubbles that would
invalidate the test results. After the sample is placed in the consolidation ring in
the oedometer, the initial load is applied. The seating load consisting of the
porous stone, loading plate, and ball bearings plus the compression load caused
by the dial indicator is considered as the initial load increment for the test. This
load should not exceed 0.005 tsf. If the sample consistency is extremely fluid-
like, a lower initial load may be necessary to prevent extrusion of the soft mate-
rial from the consolidation ring.
Succeeding load increments may be placed using the normal beam and weight
or pneumatic loading devices. The following loading schedule is typically used
for dredged material testing: 0.005, 0.01, 0.02, 0.05, 0.10, 0.25, 0.50, and 1.0 tsf.
A maximum load of 1.0 tsf should be adequate for most applications. However,
the maximum effective stress anticipated to occur at the bottom of the dredged
material deposit during its existence should be estimated and the loading
sequence extended, if necessary, to cover the full range of potential effective
stresses.
Time-consolidation data should be examined while the test is in progress to
ensure that 100-percent primary consolidation is reached for each load incre-
ment. In some cases, it may be necessary to allow each load increment to remain
for a period of several days. Rebound loadings are not normally required since
the dredged material will not typically be excavated after placement at a disposal
site (USACE 1987).
Self-Weight Consolidation Test
A test device and testing procedure were developed by Cargill (1985 and
1986) to allow determination of the compressibility characteristics of dredged
material at high void ratios. This test represents a modification to a testing
procedure developed by Bromwell and Carrier (1979) for use in analyzing
phosphate mining wastes. It is used to supplement the standard consolidation
test in order to provide e- and e-k data over the full range of anticipated void
ratios and is especially useful for hopper or hydraulically dredged materials.
I3
Appendix I Consolidation Testing
|
Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing |