Sub-Bottom Profiling to Delineate Areas of Contaminated Sediments
Category:
Geotechnical Evaluation Methods
Description:
Pelagos Corporation has developed a process to improve the efficiency of bottom sampling.
Seismic sub-bottom profiling is performed to determine locations of core samples. This reduces
the number of samples required. The system can also be used to determine dredgeability.
Port of Oakland Inner and Outer Harbors were surveyed using DGPS for NOV POS, A Raytheon
DE 719 Echo Sounder for bathymetry and a sub-bottom profiling system consisting of:
1. Energy source/receiver O.R.E. (1-12 kHz).
2. Analog recorder - EPC 3200 s.
3. Digital recorder/processor - ELICS Delphi.
System proved to be very effective in delineating a wide range of disturbed sediment deposits,
which were shown by core sampling and testing to contain various amounts of contamination.
When combined with normal sediment sampling and testing using compatible navigation
accuracy, this technique provides a more accurate delineation of contaminated areas.
Reviewer:
C. Woolley
Company / Organization(s):
Projects Completed:
Oakland Outer and Inner Harbors
Location:
Oakland, California
Completion Date:
August & September 1993
Panama, Great Lakes Dredge & Dock
San Diego Bay, U.S. Navy
Information Sources:
Literature:
Month:
May
Year:
1994
LitType:
Report/Proceedings
Publisher:
WEDA XV
Page:
33
99
Chapter 5 Other Technologies Reviewed
|