Appendix C
Test Procedures for Surface
Runoff Discharges
C.1 Introduction
This appendix provides detailed, step-by-step procedures for conducting tests
for evaluation of confined disposal facility (CDF) runoff. The background,
rationale, and tiered framework for application of these procedures are discussed in
Chapter 5 of the main text of the Upland Testing Manual (UTM). Four test
procedures are included in this appendix:
a. Simplified laboratory runoff procedure (SLRP) for water quality
evaluations.
b. Rainfall simulator/lysimeter system (RSLS) test for water quality
evaluations.
c. Water column toxicity tests using the SLRP elutriate.
d. Water column toxicity tests using the RSLS elutriate.
C.2 Simplified Laboratory Runoff Procedure for
Runoff Quality Evaluation
The SLRP was designed to simulate the water quality of precipitation runoff
from dredged material. The procedure evaluates the surface water generated on
the CDF as a result of two cases: 1) Precipitation under wet, anaerobic
conditions where consolidation is at a minimum as interstitial water is removed.
At this stage, suspended solids in precipitation generated surface water within
the CDF are possible within the range of 500 to 50,000 mg l-1; 2) The opposite
C1
Appendix C Test Procedures for Surface Runoff Discharges
|