Labeling tape
pH meter
Electrical conductivity meter
Clamp, large
Ring stand
Pipetter
Pipet tips: 1 mL, 5 mL
Polyethylene stirring rods
Polyethylene bottles: 60, 250, 500, 1,000 mL
Note: All plastic ware must be prewashed with a metal-free, nonionic
detergent solution, rinsed, soaked in 1 + 1 nitric acid for 24 hr, and
rerinsed in distilled-deionized (DDI) water.
DDI water conforming to ASTM Type II Water (ASTM D1193-99)
(ASTM 1999)
Ultrex nitric acid, concentrated
Ultrex sulfuric acid, concentrated
B. Sample preservation procedure.
a. Place two strips of labeling tape on each polyethylene sample collection
bottle. Consult the sample collection chart in Table D1, then pipette 0.5
mL DDI water and 0.5 ml concentrated Ultrex nitric acid per 100 mL of
leachate sample for metal analysis into the polyethylene bottle. For
TOC analysis, pipette 0.5 mL DDI water and 0.5 mL concentrated Ultrex
sulfuric acid into the collection bottle. Weigh the bottle and lid, and
record this weight on one strip of labeling tape.
b. On the other strip of tape, label each collection vessel with the sediment
identification, column leach apparatus number, sample number, and
parameter code. Suggested parameter codes are M = metals, C =
chloride, T = Total Organic Carbon, and PE = pH and electrical
c. Remove the lid, and securely cover each bottle with parafilm. Puncture
a small hole in the center of the parafilm with a pipette tip.
d. Attach a large clamp to a ring stand, and secure the collection bottle to
the clamp. Place the bottle under the column leach apparatus, tilting,
and elevating the bottle in such a manner that the end of the outlet tubing
D17
Appendix D Leachate Testing Procedures
|