e. After each metal/chloride and TOC leachate sample has been collected,
place a labeled, preweighed 20-mL polyethylene bottle under the column
outlet. Collect approximately 12 g of leachate. (Reweigh the bottle to
determine the exact weight of leachate.) Check the pH and electrical
conductivity of this sample on a pH meter and electrical conductivity
meter.
D.4.4 Collection and preservation of column leachate samples for
analysis of organic constituents
This procedure describes collection and preservation techniques for samples
generated from leaching of sediments, and dredged materials in laboratory
column leaching apparatus. Column leachate samples are collected in amber
glass bottles, in a prescribed manner. The samples are stored at 4 EC, then
analyzed for polycyclic aromatic hydrocarbons (PAHs), polychlorinated
biphenyls (PCBs), and other related organic constituents.
A. Materials.
Analytical balance
Labeling tape
Fraction Collector, with the capability of time-based sample collection in
seconds or minutes (Example: Eldex Laboratories, Inc., Model UP-1A)
Silicone tubing, plasticizer-free, additive-free (1/8 in. ID H 1/4 in. OD
and 1/4 in. ID H 3/8 in. OD)
Amber glass bottles with Teflon-lined lids, precleaned to EPA Level 1:
1,000 mL
Distilled-deionized (DDI) water conforming to ASTM Type II (ASTM
D1193-99) (ASTM 1999).
Methanol, pesticide grade or equivalent
B. Procedure for preparation of fraction collector.
a. Assemble the Fraction Collector according to manufacturer's
instructions, and place it on the table near the Column Leach Apparatus
described previously. Attach a 12-in. section of silicone tubing (1/8-in.
ID H 1/4-in. OD, cleaned with methanol and rinsed repeatedly with DDI
water) to the outlet tubing on the Column Leach Apparatus.
b. Attach 1/8-in. ID silicone tubing to the bottom of the glass tubes on the
Fraction Collector. (This silicone tubing will be later connected to
1/8-in. stainless steel tubing inserted in lids used to cover the amber
bottles during sample collection.)
D19
Appendix D Leachate Testing Procedures