ERDC TN-DOER-C10
March 2000
Example for transferring samples from dosing plate to reading plate
DOSING PLATE 1
Column 1
Column 2
Column 3
Column 4
Column 5
Column 6
Column 7
Column 8
Column 9
Column 10
Column 11
Column 12
A
Iso-
Iso-
Iso-
Iso-
Iso-
Iso-
Sample 1
Sample 1
Sample 1
Sample 1
Sample 1
Sample 1
octane
octane
octane
octane
octane
octane
Extract 1
Extract 1
Extract 2
Extract 2
Extract 3
Extract 3
B
Sample 2
Sample 2
Sample 2
Sample 2
Sample 2
Sample 2
1 pg/mL
1 pg/mL
1 pg/mL
1 pg/mL
1 pg/mL
1 pg/mL
Extract 1
Extract 1
Extract 2
Extract 2
Extract 3
Extract 3
C
Sample 3
Sample 3
Sample 3
Sample 3
Sample 3
Sample 3
2.5 pg/mL
2.5 pg/mL
2.5 pg/mL
2.5 pg/mL
2.5pg/mL
2.5 pg/mL
Extract 1
Extract 1
Extract 2
Extract 2
Extract 3
Extract 3
D
Sample 4
Sample 4
Sample 4
Sample 4
Sample 4
Sample 4
5 pg/mL
5 pg/mL
5 pg/mL
5 pg/mL
5 pg/mL
5 pg/mL
Extract 1
Extract 1
Extract 2
Extract 2
Extract 3
Extract 3
E
Sample 5
Sample 5
Sample 5
Sample 5
Sample 5
Sample 5
10 pg/mL
10 pg/mL
10 pg/mL
10 pg/mL
10 pg/mL
10 pg/mL
Extract 1
Extract 1
Extract 2
Extract 2
Extract 3
Extract 3
F
Sample 6
Sample 6
Sample 6
Sample 6
Sample 6
Sample 6
25 pg/mL
25 pg/mL
25 pg/mL
25 pg/mL
25 pg/mL
25 pg/mL
Extract 1
Extract 1
Extract 2
Extract 2
Extract 3
Extract 3
G
Sample 7
Sample 7
Sample 7
Sample 7
Sample 7
Sample 7
50 pg/mL
50 pg/mL
50 pg/mL
50 pg/mL
50 pg/mL
50 pg/mL
Extract 1
Extract 1
Extract 2
Extract 2
Extract 3
Extract 3
H
100
100
100
100
100
100
Sample 8
Sample 8
Sample 8
Sample 8
Sample 8
Sample 8
pg/mL
pg/mL
pg/mL
pg/mL
pg/mL
pg/mL
Extract 1
Extract 1
Extract 2
Extract 2
Extract 3
Extract 3
Combine 25 L
Combine 25 L
Combine 25 L
Combine 25 L
Combine 25 L
Combine 25 L
each from row A,
each from row A,
each from row A,
each from row A,
each from row A,
each from row A,
columns 1 and 2,
columns 11 and
columns 9 and 10,
columns 7 and 8,
columns 3 and 4,
columns 5 and 6,
of dosing plate
12, of dosing plate
of dosing plate
of dosing plate
of dosing plate
of dosing plate
into reading plate
into reading plate
into reading plate
into reading plate
into reading plate
into reading plate
row A, column 1.
row A, column 6.
row A, column 5.
row A, column 4.
row A, column 2.
row A, column 3.
Repeat for rows
Repeat for rows
Repeat for rows
Repeat for rows
Repeat for rows
Repeat for rows
B-H.
B-H.
B-H.
B-H.
B-H.
B-H.
The second half of the reading plate will be used for samples
READING PLATE
from the second dosing plate
Column 1
Column 2
Column 3
Column 4
Column 5
Column 6
Column 7
Column 8
Column 9
Column 10
Column 11
Column 12
A
Iso-
Iso-
Iso-
Sample 1
Sample 1
Sample 1
octane
octane
octane
Extract 1
Extract 2
Extract 3
B
Sample 2
Sample 2
Sample 2
1 pg/mL
1 pg/mL
1 pg/mL
Extract 1
Extract 2
Extract 3
C
Sample 3
Sample 3
Sample 3
2.5pg/mL
2.5 pg/mL
2.5 pg/mL
Extract 1
Extract 2
Extract 3
D
Sample 4
Sample 4
Sample 4
5 pg/mL
5 pg/mL
5 pg/mL
Extract 1
Extract 2
Extract 3
E
Sample 5
Sample 5
Sample 5
10 pg/mL
10 pg/mL
10 pg/mL
Extract 1
Extract 2
Extract 3
F
Sample 6
Sample 6
Sample 6
25 pg/mL
25 pg/mL
25 pg/mL
Extract 1
Extract 2
Extract 3
G
Sample 7
Sample 7
Sample 7
50 pg/mL
50 pg/mL
50 pg/mL
Extract 1
Extract 2
Extract 3
H
100
100
100
Sample 8
Sample 8
Sample 8
pg/mL
pg/mL
pg/mL
Extract 1
Extract 2
Extract 3
27
|